NEW QUESTION 10
Refer to the Exhibit.
Note the yellow arrow. A Data Center Engineer notices that the LED is blinking blue and amber alternating at one second intervals. What does this indicate?
- A. Node in Service Mode
- B. Node is Degraded
- C. System not initialized
- D. System is booting
Answer: A
NEW QUESTION 11
What does a Storage Administrator need to consider about Resource Balance when assigning volumes?
- A. Whether the appliance is offline
Appliance failure status
Capacity utilization - B. Whether the Cluster is offline
Node failure status
I/O utilization - C. Whether the Node is offline
Appliance failure status
Node utilization - D. Whether the appliance is online
Appliance failure status
Cluster utilization
Answer: A
Explanation:
Reference: https://volumes.blog/2020/05/18/what-is-powerstore-part-11-resource-balancer/
NEW QUESTION 12
What are the IP requirements for ICW on PowerStore X and PowerStore T models?
- A. PowerStore T requires four management IP addresses and PowerStore X requires six management IP addresses
- B. PowerStore T requires three storage IP addresses and PowerStore X requires five storage IP addresses
- C. PowerStore T requires five management IP addresses and PowerStore X requires six management IP addresses
- D. PowerStore T requires seven storage IP addresses and PowerStore X requires three storage IP addresses
Answer: C
NEW QUESTION 13
When planning rack layout, why should base enclosures be grouped together?
- A. Power distribution requirements
- B. Hot aisle requirement
- C. Ease of cable management
- D. Rack weight balance
Answer: A
NEW QUESTION 14
1.a.1 What is the maximum number of appliances that can be connected to form a cluster?
- A. 1 in a PowerStore T cluster, 1 in a PowerStore X cluster
- B. 4 in a PowerStore T cluster, 1 in a PowerStore X cluster
- C. 4 in a PowerStore T cluster, 4 in a PowerStore X cluster
- D. 1 in a PowerStore T cluster, 4 in a PowerStore X cluster
Answer: B
NEW QUESTION 15
Refer to the Exhibit.
A Network administrator is failing to discover a PowerStore T system using the PowerStore Discovery Utility. What might be the issue?
- A. Port 54 needs to be enabled
- B. Port 54 has not been set to trunk mode
- C. Discovery network uses only native VLAN
- D. Dedicated port needs to be used for discovery network
Answer: D
NEW QUESTION 16
What is a requirement for the Import External Storage migration feature?
- A. PowerPath host-based multipathing software
- B. Direct Fibre Channel connections between storage systems
- C. PowerStore LACP bonded ports are tagged for replication
- D. PowerStore Global Storage Discovery IP address must be configured
Answer: D
NEW QUESTION 17
What is the maximum number of snapshot rules per cluster?
- A. 0
- B. 1
- C. 2
- D. 3
Answer: C
NEW QUESTION 18
What is a way to verify the data path connectivity between a source VNX2 storage system and the PowerStore system when configuring an import session?
- A. Verify host initiators on PowerStore Manager
- B. Review Server Manager MPIO properties
- C. Use the VNX2 SP ping operation
- D. Examine Fibre Channel zoning
Answer: C
NEW QUESTION 19
1.a.1 What is the maximum number of appliances that can be connected to form a cluster?
- A. 1 in a PowerStore T cluster, 1 in a PowerStore X cluster
- B. 4 in a PowerStore T cluster, 1 in a PowerStore X cluster
- C. 4 in a PowerStore T cluster, 4 in a PowerStore X cluster
- D. 1 in a PowerStore T cluster, 4 in a PowerStore X cluster
Answer: B
Explanation:
Reference:
https://www.delltechnologies.com/en-us/collaterals/unauth/white-papers/products/storage/h18149- dell-emc-powerstore-platform-introduction.pdf
NEW QUESTION 20
A storage administrator has provisioned 10 x 2GB volumes. 400MB of data is written to each of the ten volumes. What is the Thin Savings ratio for this configuration?
- A. 6:1
- B. 3:1
- C. 5:1
- D. 4:1
Answer: A
NEW QUESTION 21
Use the PowerStore Manager simulator to configure the BaseEnclosure-NodeA-IoModule1-FEport0 as a replication port. When you have finished using the simulator, Click Next.
Answer:
Explanation:
check the answer below in explanation.
Explanation
Below are the exhibits solution for this simulation.








NEW QUESTION 22
How is the upgrade process on a multi-appliance cluster run?
- A. Master appliance primary node first, then the peer node
- B. On one node at a time
- C. In parallel on all nodes
- D. On all primary nodes first, then peer nodes
Answer: A
NEW QUESTION 23
Match the CLI command to the appropriate configuration.
Answer:
Explanation:
NEW QUESTION 24
Correctly arrange the sequence of the write operation in PowerStore.
Write Operation
The graphic explains the process when the PowerStore receives a write request.
1: Step 1.
In this example, an I/O enters Node B and is saved within the Node
DRAM memory. The I/O is analyzed to determine:
1. What type of I/O it is.
2. What resource it is intended for.
3. The location within the resource being updated or requested.
4. And other metadata information.
2: Step 2.
If the I/O is determined to be a write, the data is copied into the write cache on the NVRAM drives. After the information is stored within the write cache, the information stored within the DRAM memory is considered clean as it no longer has the latest copy of the information. This data then becomes part of the read cache, until it is later replaced in cache by newer or more highly accessed dat
a.
3: Step 3.
For each write I/O that enters the system, the information is passed
between the Nodes using tokens. This operation updates the peer node that a new write has been received and that it has the newest copy of the data. A token includes information about the I/O such as what resource was updated and the address within the resource that was updated. A token also includes information Data Efficiency about the location the I/O was saved to within the write cache. If the peer Node requests that information, the Node can access the data within the NVRAM drives using its own internal channels.
4: Step 4.
After the information is safely stored on the nonvolatile media of the NVRAM drives and all other actions are complete, the host is acknowledged.
5: Step 5.
After the host is acknowledged, data is copied from the Write Cache and is passed through the deduplication and compression logic. The remaining data is then assembled into 2 MB stripes and saved to the back-end storage.
Answer:
Explanation:
Reference:
https://www.delltechnologies.com/resources/en-us/asset/white-papers/products/storage/h18151-dell-emc-powerstore-data-efficiencies.pdf
NEW QUESTION 25
How is the upgrade process on a multi-appliance cluster run?
- A. Master appliance primary node first, then the peer node
- B. On one node at a time
- C. In parallel on all nodes
- D. On all primary nodes first, then peer nodes
Answer: A
Explanation:
Explanation
NEW QUESTION 26
Use the simulator to determine how many logical ports are currently marked for replication on the PowerStore appliance.
Note: It is necessary to close (x) the simulator window before you can select a response to this question.
- A. 0
- B. 1
- C. 2
- D. 3
Answer: B
NEW QUESTION 27
What is the recommended Windows multi-pathing policy for block volumes on a PowerStore array?
- A. Least QueueDepth
- B. FailOver
- C. Round-Robin
- D. Least Weighted Paths
Answer: C
NEW QUESTION 28
An administrator receives an alert on a PowerStore Cluster with three appliances:
The appliance A1 is projected to run out of space in 8 days Capacity utilization is above 90 percent Which tools are available to assist the Administrator with a potential resolution?
- A. Space reclamation wizard
- B. Assisted Migration
- C. System Optimization
- D. Thin provision conversion wizard
Answer: B
NEW QUESTION 29
A PowerStore T cluster has 3 appliances. Users are unable to access NAS services. What might be the issue?
- A. Resource balancer service has failed
- B. Master appliance is off-line
- C. Trial license is expired
- D. NAS appliance failover is incorrectly configured
Answer: D
NEW QUESTION 30
An administrator is trying to set a performance policy while creating a Thin Clone of a volume group. Why is the option to set performance policy unavailable?
- A. Volumes in the volume group are not mapped to any hosts
- B. Performance policy can only be set on a Thin Clone volume
- C. Thin Clones cannot be created using a volume group
- D. No Volumes are added in the volume group
Answer: C
NEW QUESTION 31
Which type of network is used for storage migration between appliances?
- A. Inter-node network
- B. Intra-Cluster Management network
- C. Storage network
- D. Intra-Cluster Data network
Answer: B
Explanation:
Explanation/Reference: https://www.dell.com/support/manuals/en-pk/powerstore/pwrstr-ntwk-plang/powerstore-t-model- appliance-networks?guid=guid-97a3e988-c1bc-4f51-a445-3af23f19da1b&lang=en-us
NEW QUESTION 32
A PowerStore X system is being implemented using Dell EMC S5248F-ON Ethernet switching as data switches.
What is required when configuring the VLT interconnects on the data switches?
- A. On each switch, select the switch management port MAC as the VLT MAC
- B. Set the VLT connection to the switch default VLAN
- C. Configure the VLT MACs with a matching unique made-up address
- D. Assign the switch default route for the VLT traffic
Answer: A
NEW QUESTION 33
......