Get 2021 Updated Free Huawei H12-411 Exam Questions & Answer [Q39-Q55]

Share

Get 2021 Updated Free Huawei H12-411 Exam Questions & Answer

H12-411 Dumps PDF and Test Engine Exam Questions


Huawei H12-411 Exam Syllabus Topics:

TopicDetails
Topic 1
  • Basic knowledge of air-cooled air conditioning
  • Important parameters of data center infrastructure
Topic 2
  • Huawei low-voltage power distribution products
  • Basic interface and communication protocol
Topic 3
  • Monitoring system architecture
  • Data center power distribution system
  • Classification of batteries
Topic 4
  • Overview of lightning protection grounding system
  • Accident probability and personnel qualifications
Topic 5
  • Main functions of the monitoring system
  • Data center infrastructure construction safety
Topic 6
  • Basic concepts of low-voltage power distribution
  • Data center infrastructure
Topic 7
  • Overview of fire protection system
  • Huawei UPS products
  • Computer room monitoring system
Topic 9
  • Data Center Monitoring System
  • Main components of low-voltage power distribution
  • Overview of the monitoring system
Topic 10
  • Development history of data center infrastructure
  • Huawei Data Center Facility component product documentation
Topic 11
  • Classification of low-voltage power distribution grounding
  • Classification of air conditioning systems
Topic 12
  • Huawei certified HCIA-Data Center Facility V1.0
  • Main components of data center infrastructure
Topic 13
  • Data center cooling system
  • Introduction to PPE protection
  • Other systems in the data center

 

NEW QUESTION 39
The STS Static Transfer Switch enables switching between different input power supply and provides dual power supply for single power load.

  • A. FALSE
  • B. TRUE

Answer: B

 

NEW QUESTION 40
Air conditioning has three major indicators; the three major indicators refer to (). (Multiple Choice)

  • A. Temperature
  • B. Humidity
  • C. Cleanliness
  • D. Dryness

Answer: A,B,C

 

NEW QUESTION 41
The role of the safety valve in the battery construction prevents excessive internal pressure and drains the excess ().

  • A. Electrolyte
  • B. Hydrogen H2
  • C. Water vapor H20
  • D. Oxygen 02

Answer: B

 

NEW QUESTION 42
At present, the communication methods used by the Dynamic environment monitoring system are (). (Multiple choice)

  • A. DGT
  • B. Modbus
  • C. Dry Contact
  • D. SNMP

Answer: A,B,C,D

 

NEW QUESTION 43
Fuses can protect the personal safety in case of the equipment earth leakage.

  • A. FALSE
  • B. TRUE

Answer: A

 

NEW QUESTION 44
There are three different categories of earthing (TN, TT and IT) in low voltage distribution systems. The second capital letter represents ().

  • A. shows the relationship between neutral N and protective earth PE
  • B. Indicates the relationship of the power system to the exposed conductive parts of the power receiving system
  • C. Indicates the relationship of the power system on the ground
  • D. Said the relationship between power receiving system exposed conductive parts and the ground

Answer: D

 

NEW QUESTION 45
Huawei dynamic environment monitoring system, which equipment at the data collection layer can pass the underlying components (UPS, precision air conditioning, etc.) information to the monitoring software?

  • A. server
  • B. camera
  • C. ECC800
  • D. entrance guard

Answer: C

 

NEW QUESTION 46
12V battery consists of 6 2V battery cells.

  • A. FALSE
  • B. TRUE

Answer: B

 

NEW QUESTION 47
The following () air supply methods are mainly applicable to the craft air conditioners in lower work area where there is a large amount of waste heat to be taken away.

  • A. middle air-supply
  • B. bottom supply and bottom return
  • C. bottom supply and upper return
  • D. upper supply and bottom return

Answer: C

 

NEW QUESTION 48
The condensed water of air conditioning is air after cooler cooling, formed by the condenser.

  • A. FALSE
  • B. TRUE

Answer: B

 

NEW QUESTION 49
Cryogenic components improve the continuous low pressure caused by low temperature start-up, thus allowing the air conditioner to start up normally.

  • A. FALSE
  • B. TRUE

Answer: B

 

NEW QUESTION 50
In air-conditioning systems, the role of () is to cool the high-temperature and high-pressure gas discharged from the compressor by using water-cooled or air-cooled to release heat to the outside world.

  • A. Condenser
  • B. compressor
  • C. Expansion valve
  • D. Evaporator

Answer: A

 

NEW QUESTION 51
For the same MCB circuit breaker, the rated ultimate short-circuit breaking capacity leu is generally less than the rated operating short-circuits breaking capacity Ics.

  • A. FALSE
  • B. TRUE

Answer: A

 

NEW QUESTION 52
The humidifier that Huawei row-level precision air conditioner uses is the infrared humidifier.

  • A. False
  • B. True

Answer: A

 

NEW QUESTION 53
Which of the following does not belong to the four major components of air conditioning?

  • A. Fan
  • B. Condenser
  • C. Evaporator
  • D. Compressor

Answer: A

 

NEW QUESTION 54
According to the concentration degree of equipment, air conditioning system can be divided into (). (Multiple choice)

  • A. decentralized
  • B. Semi-centralized
  • C. Centralized
  • D. Mixed

Answer: A,B,C

 

NEW QUESTION 55
......

Verified H12-411 exam dumps Q&As with Correct 185 Questions and Answers: https://www.pass4training.com/H12-411-pass-exam-training.html